ELECTRONIC RCBO JEL4A 6kA 2P 10A/30mA

25,00

(In Stock)

COD: 00783 Categorie: ,

Caratteristiche tecniche
INTERRUTTORE DIFFERENZIALE MAGNETOTERMICO

DESCRIPTION OF THE OPERATING SYSTEM »RCBO JEL4A is with enhanced sensibility and fast – operating protection devices applicable in circuits withharmonic or direct pulsating current component presence.”Phase line + neutral + leakage “protection circuit breaker JEL4A is applied to the single-phase residentialcircuit of 50Hz or 60Hz, rated voltage 230V, to protect leakage, civil electrical overload and short circuit. Theproduct is provided with many advantages such as small size, high breaking capacity, cutting off zero-line,live line at the same time, and leakage protecting in the case of reverse wiring live line.FUNCTIONS »? Switching off heavy-loaded electrical circuits at short circuit or overload.? Switching off heavy-loaded electrical circuits at insulation damage of the conductors to the consumers.? Switching off heavy-loaded electrical circuits at presence of a person and animals under voltage.? Switching off consumers at harmonic pres ence due to luminescent lights.? Switching off consumers in DC circuits at fault currents presence.? Used to protect not only particular consum ers/circuits, but also the whole panel.? Remarkable with high reliability of current characteristics.? Control: manual switching on and automatic switching off at failure in the insulation after the breaker.TECHNICAL DATA »? Mode: Electronic? Type: A for AC/DC current? Rated operating voltage Ue: 230/240V 50/60 Hz? Insulation voltage Ui: 500V? Circuit breaker rated current: according to the table? Residual current responsiveness: 30; 300mA? Break time under I?n: =0.1s? Circuit breaker tripping curve: C? Energy limiting class: 3? Breaking capacity: 6 000A? Rated impulse withstand voltage (1.5/50)? Uimp: =4000V? Dielectric test voltage at ind.Freq. for 1min: 2kV? Polution degree: 2? Electrical life: 4 000 cycles? Mechanical life: 10 000 cycles? IP code: IP>20? Indication for operating (switched on) position? Terminal connection type: Cable? Pin-type busbar? U-type busbar? Terminal size top/bottom for cable: 25mm2? Terminal size top/bottom for busbar: 25 mm2? Tightening torque: 2.5Nm? Reference temperature for setting of thermal element: 30°C? Ambient temperature: -10°C + 65°C? Installation altitude: up to 2000 m 

Tipo A
Modello JEL4A
Tensione nominale 240V
Corrente nominale 10A
Capacità di interruzione 6 kA
Numero dei poli 1
   
Corrente di dispersione 30mA
Tipo RCBO
Dimensione complessiva (mm) L:78/W:36/H:81